| MR-I
|
|
TYPE:
LV & MV Three Phase
Overcurrent
Transformer Feeder Protection Relay
KEY FEATURES: Three
pole Overcurrent + High Set. Eight IEC & IEEE
Protection Curves. Eight Segment LED with Breaker
fail Protection & Time Stamping to 10 ms.
Two setting option switched by digital input.
ANSI Nos. 50, 50BF,
51
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-I
|
|
TYPE:
LV & MV Overcurrent
Transformer Feeder Protection Relay
KEY FEATURES: Three
pole Overcurrent + High Set. Four Segment LED
with Breaker fail. Protection & Time Stamping
to 10 ms.
ANSI Nos. 50, 51
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MR-IE
|
|
Click
image to enlarge
TYPE:
LV & MV Overcurrent
& Earth Fault Transformer Feeder Protection
Relay
KEY FEATURES: Three
pole Overcurrent + High Sets & Earth Fault
+ High Set - Three levels. Eight IEC & IEEE
Protection Curves. Eight Segment LED with Breaker
fail Protection & Time Stamping to 10 ms.
ANSI Nos. 50, 50BF,
51, 50n, 51n
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-IE
|
|
TYPE:
LV & MV Overcurrent
& Earth Fault Transformer Feeder Protection
Relay
KEY FEATURES: Three
pole Overcurrent + High Sets & Earth Fault
+ High Set. Four Segment LED with Breaker fail.
Protection & Time Stamping to 10 ms.
ANSI Nos. 50, 51,
50n, 51n
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-E
|
|
TYPE:
LV & MV Earth Fault
Relay
KEY FEATURES: Earth
Fault + High Set. Four Segment LED with Breaker
fail. Protection & Time Stamping to 10 ms.
ANSI Nos. 50n, 51n
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-ED
|
|
TYPE:
LV & MV Directional
Earth Fault Relay
KEY FEATURES: Low
set functions - Definite time, Normal Inverse,
Very Inverse & Extremely Inverse time. High
Set Instantaneous or Definite time.
ANSI Nos. 67n
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-EX
|
|
Click
image to enlarge
TYPE:
LV & MV Sensitive
Directional Earth Fault Relay
KEY FEATURES: Single
Phase Relay with High set and Low set functions.
ANSI Nos. 67n
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-ID
|
|
TYPE:
LV & MV Three Phase
Directional Overcurrent Relay
KEY FEATURES: Low
set functions - Definite time, Normal Inverse,
Very Inverse & Extremely Inverse time. High
Set Instantaneous or Definite time.
ANSI Nos. 50, 51,
67
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-IDS
|
|
TYPE:
LV & MV Three Phase
Sensitive Directional Overcurrent Relay
KEY FEATURES: Two
stage Low set functions - Definite time, Normal
Inverse, Very Inverse & Extremely Inverse
time. High Set Instantaneous or Definite time.
ANSI Nos. 50, 51,
67
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
Back to top>>
|
| MRI-IED
|
|
TYPE:
LV & MV Three Phase
fully Directional Overcurrent & Earth Fault
Relay
KEY FEATURES: All
functions separately settable and with 10 ms Time
Stamping
ANSI Nos. 50, 51,
67, 50n, 51n, 67n
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRI-REF
|
|
TYPE:
LV & MV Restricted
Earth Fault Relay
KEY FEATURES: High
Impedance Differential Current
Unit Protection scheme with instantaneous tripping.
ANSI Nos. 64R
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRDT
|
|
TYPE: Biased Transformer
Differential Relay
KEY FEATURES: Two or three winding. Transformers.
Digital Relay with LCD Display. Two stage Biased
Differential Protection.
ANSI Nos. 87T
CASE: 19 Inch Rack format
|
| >>
read
more PDF |
|
Back to top>>
|
| MIRD-T2
|
|
TYPE:
Biased Transformer Differential
Relay
KEY FEATURES: Two
winding Transformers with two stage. Biased Differential
Protection via switched settings.
ANSI Nos. 87
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
| MRAR
|
|
TYPE:
Breaker Auto Reclose
Relay
KEY FEATURES: Up
to four shot Auto Reclose Relay with adjustable
Fault, Dead, Close & Reclaim times. Maintenance
Alarm & Trip feature.
ANSI Nos. 79
CASE: Draw out case
size 100 ( 212 deep ). Panel cut out 99 width
x 159 height.
|
| >>
read
more PDF |
|
|
Back to top>>
|